Control tab – Extron Electronics DMS 1600_2000_3200_3600 User Guide User Manual
Page 103

DMS 1600, DMS 2000, DMS 3200, and DMS 3600 • HTML Operation
97
Control Tab
Set and View Ties Page
You can create ties on the Set and View Ties page (see figure 65). Access the Set and View
Ties page by clicking the
Control
tab.
2
1
1
Figure 65.
Set and View Ties Page
The page consists of a matrix of input (rows) and output (columns) selection buttons of two
colors:
•
Amber — indicate ties.
•
Gray — indicate no ties.
Creating or deleting a tie
Make or break a tie as follows:
1.
Move the mouse over the matrix of input and output selection buttons. Click a button to
•
Create a pending tie of the input and output associated with that button
•
Create a pending untie of the input and output associated with that button
A “
P
” (for pending) appears in the button (see figure 65 [
a
]).
NOTES:
•
Because of command length limitations in the browser, you can make a
maximum of 30 connections with a single
Take
command (step 2).
•
To tie an input to all outputs, click the input number for that input.
2.
Click
Take
(
b
) to make the configuration changes or
Cancel
to abandon the
configuration changes.