ATTENTION: Review the reset modes carefully. Using the wrong reset mode may

result in unintended loss of flash memory programming, port reassignment, or a
controller reboot.

NOTE: The reset modes listed below close all open IP and Telnet connections and close

all sockets. Also, the following modes are separate functions, not a continuation from
Mode 1 to Mode 5.

Reset Mode Comparison/Summary

Mode Activation

Result

Purpose & Notes

1

Hold down the recessed Reset button
while applying power to the switcher.

NOTE: After a mode 1 reset is

performed, update the switcher
firmware to the latest version. Do
not operate the switcher firmware
version that results from the
mode 1 reset. If you want to use
the factory default firmware, you
must upload that version again
(see

Updating Firmware

on

page 72).

The switcher reverts to the factory default firmware. Event
scripting will not start if the switcher is powered on in
this mode. All user settings and files, such as the current
configuration and IP settings, are maintained.

NOTE: If you do not want to update firmware, or you

performed a mode 1 reset by mistake, cycle power
to the switcher to return to the firmware version that
was running before the mode 1 reset. Use the 0Q
SIS command to confirm that the factory default
firmware is no longer running (look for the asterisk [*]
following the version number).

Use mode 1 to revert
to the factory default
firmware version if
incompatibility issues
arise with user-loaded
firmware.

3

Hold down the Reset button for about
3 seconds, until the Reset LED blinks
once, then press Reset momentarily
(<1 second) within 1 second.

Mode 3 turns events on or off. During resetting, the Reset
LED flashes 2 times if events are starting, 3 times if events
are stopping.

Mode 3 is useful for
troubleshooting.

4

Hold down the Reset button for
about 6 seconds, until the Reset
LED blinks twice (once at 3 seconds
and again at 6 seconds). Then press
Reset momentarily (<1 second) within
1 second.

Mode 4:

Enables ARP capability.

Sets the IP address to the factory default

Sets the subnet address to the factory default.

Sets the gateway address to the factory default.

Sets port mapping to the factory default.

Turns DHCP off.

Turn events off.

The Reset LED flashes three times in quick succession
during the reset.

Mode 4 enables you
to set IP address
information using ARP
and the MAC address.

5

Hold down the Reset button for
about 9 seconds, until the Reset
LED blinks three times (once at
3 seconds, again at 6 seconds, and
then again at 9 seconds). Then press
Reset momentarily (<1 second) within
1 second.

Mode 5 performs a complete reset to factory defaults
(with the exception of the firmware):

Does everything mode 4 does.

Resets most settings including:

clears all ties and presets

clears all output mutes

clears all I/O grouping

Resets all IP options.

Removes/clears all files for the switcher.

The reset LED flashes three times in quick succession
during the reset.

Mode 5 is useful if
you want to start over
with configuration
and uploading or to
replace events.
Same as

E

ZQQQ

}

SIS command.