R&M Materials Handling WIRE ROPE HOISTS Service User Manual
Page 104

R&M Materials Handling, Inc.
4501 Gateway Boulevard
Springfield, Ohio 45502
P.: (937) 328-5100
FAX: (937) 325-5319
104/130
R&M Materials Handling, Inc. reserves the right to alter or amend the above information without notice.
!
Setup the condition monitoring unit always after load sensor amplifier adjustment! Refer to
separate service manual for condition monitoring unit.
Terminal Signal
To
1
0 VDC
Condition monitoring unit: 2
2
0 VDC
Load sensor (-Exc)
3
Signal
Condition monitoring unit: 3
4 Signal
Not
connected
5
10 VDC
Condition monitoring unit: 4
6
10 VDC
Load sensor (+Exc)
7
-IN
Load sensor (Out)
8
+IN
Load sensor (Out)
9
SHLD
Load sensor (shield)
10
4 VDC
Not connected