63 — dsc ptm trigger 1, 64 — dsc ptm trigger 2, 65 — scs ptm trigger 1 – Xerox ALLY PLUSTM 6287 User Manual
Page 64

6287 ALLY PLUS User’s Manual
Page 3-24
To send the Xerox 4045 reset sequence requires 13 characters the first
trigger (¢), the second trigger ($), the hexadecimal reset sequence
(1B2B580D0A) and an invalid character/terminator (¢):
¢$1B2B580D0A¢
63 — DSC PTM trigger 1
This option tells the ALLY PLUS which character in the incoming DSC
data stream will activate pseudo transparency mode. If no pseudo
transparency is needed (see Option #62), this option has no effect. To set or
change the trigger, enter the appropriate hexadecimal value:
!ALLY!63=1B;
a DSC cent sign (¢) (default)
!ALLY!63=16;
a DSC vertical bar (|) is common
Note: The trigger 1 character should be reserved for this use only. Any
other use of the trigger 1 character may produce unpredictable results.
64 — DSC PTM trigger 2
This option has no effect unless the two-trigger method (see Option #62) is
selected. The default second trigger is 1A, which is a DSC dollar sign ($).
Here are some examples of programming this option:
!ALLY!64=1A;
a DSC dollar sign ($) (default)
!ALLY!64=36;
a DSC logical not (¬) is popular
65 — SCS PTM trigger 1
This option sets trigger 1 for SCS pseudo transparency. Option #62 must be
set for 01 or 02 for this option to have an effect. Some examples:
!ALLY!65=4A;
an SCS cent sign (¢) (default)
!ALLY!65=4F;
an SCS vertical bar (|) is also popular
Note: The trigger 1 character should be reserved for this use only. Any
other use of the trigger 1 character may produce unpredictable results.