6287 ULTRA COMPATIBILITY

24 — Reserved

This option is reserved in the current ULTRA firmware, and it has no

equivalent in the ALLY PLUS.

25 — Centronics or Dataproducts Parallel

This option has no equivalent in the ALLY PLUS, because the ALLY

PLUS supports only Centronics parallel interfacing.

26 — Intervention Required

If this option is set to a value of “N,” ALLY PLUS Option #52 is set to 00.

The General Configuration Report will display a “0.” If this option is set to

“Y,” the setting of ALLY PLUS Option #52 is determined by ULTRA

Option #27.

27 — Intervention Required Delay

If ULTRA Option #26 is set to “Y,” the setting of this option determines the

value of ALLY PLUS Option #52. The ULTRA decimal value is executed

as though it were the equivalent ALLY PLUS hexadecimal value. The

General Configuration Report will display the decimal number of minutes

selected by this option.
Note: The smallest delay allowed by the ALLY PLUS is 1 minute, while the

ULTRA can send an Intervention Required message immediately. If the

ULTRA configuration command is set to 0 (immediate), it is executed as

though it were an ALLY PLUS value of 01 (1 minute).

28 — Reserved

This option is reserved in the current ULTRA firmware, and it has no

equivalent in the ALLY PLUS.

29 — Reserved

This option is reserved in the current ULTRA firmware, and it has no

equivalent in the ALLY PLUS.