beautypg.com

15 special instructions, Sel rbn, Sel mbn – NEC PD754144 User Manual

Page 290: Geti taddr

background image

CHAPTER 11 INSTRUCTION SET

290

User’s Manual U10676EJ3V0UM

11.4.15 Special instructions

SEL RBn

Function: RBS

n n = N

1-0

: 0-3

Sets 2-bit immediate data n to the register bank select register (RBS).

SEL MBn

Function: MBS

n n = N

3-0

: 0, 4, 15

Transfers 4-bit immediate data n to the memory bank select register (MBS).

GETI taddr

Function: taddr = T

5-0

, 0: 20H to 7FH

[MkI mode]

When table defined by TBR instruction is referenced

PC

11-0

(taddr)

3-0

+ (taddr+1)

When table defined by TCALL instruction is referenced

(SP–1)

PC

7-4

, (SP–2)

PC

3-0

(SP–3)

MBE, RBE, 0, 0

(SP–4)

PC

11-8

PC

11-0

(taddr)

3-0

+ (taddr+1)

SP

SP–4

When table defined by instruction other than TBR and TCALL is referenced

Executes instruction with (taddr) (taddr+1) as op code

[MkII mode]

When table defined by TBR instruction is referenced

Note

PC

11-0

(taddr)

3-0

+ (taddr+1)

When table defined by TCALL instruction is referenced

Note

(SP–2)

Ч, Ч, MBE, RBE

(SP–3)

PC

7-4

, (SP–4)

PC

3-0

(SP–5)

0, 0, 0, 0, (SP–6)

PC

11-8

PC

11-0

(taddr)

3-0

+ (taddr+1), SP

SP–6

When table defined by instruction other than TBR and TCALL is referenced

Executes instruction with (taddr) (taddr+1) as op code

Note The address specified by the TBR and TCALL instructions is limited to 0000H to 0FFFH.

I/II

This manual is related to the following products: