NEC PD754144 User Manual
Page 158
CHAPTER 6 PERIPHERAL HARDWARE FUNCTION
158
User’s Manual U10676EJ3V0UM
Figure 6-43. Timing of Count Operation
Remark
m: Set value of timer counter module register (TMOD1)
n:
Set value of timer counter modulo register (TMOD2)
Count pulse (CP)
Timer counter modulo
register (TMOD2)
Timer counter count
register (T2)
Timer counter count
register (T1)
TOUT F/F
0
1
2
n
255
0
1
n–1
n
0
1
2
n
Set
Timer start command
2
Timer counter modulo
register (TMOD1)
m
0
m–1
m
0
Match
Match
This manual is related to the following products: