Sagem 3p@c – Sagem 4450E User Manual
Page 42
SAGEM 3P@C
3P@C Installation Manual
Page 2-19
Reproduction and communication in any form prohibited without the written permission of SAGEM SA
Of the above, the different states of LINK and ACT indicators show the port operating status. For
details, refer to Table 2-13.
1.1.1.18
1.1.1.18
1.1.1.18
1.1.1.18
Indicators of the DS-2FMM module
Table 2-13 Status definitions of the LINK and ACT LEDs on the DS-2FMM module
LED
Color
Display
state
Description
Solid on
After a stable connection between a port and the
equipment is established, the indicator of the port
stays solid on.
LINK
Green
Off
The link on the port is down.
Flashing
Data are being received/transmitted on the
optical port.
ACT
Yellow
Off
No data are being received/transmitted on the
optical port.
1.1.1.19
1.1.1.19
1.1.1.19
1.1.1.19
Interface features of the DS-2FMM module
Table 2-14 Interface features of the DS-2FMM module
Module
type
Quantity of
interfaces
Interface
type
Interface
attributes
Fiber
specification
s
Transmission
distance
DS-2FMM
2
SC
100Base-
FMM
62.5/125 µm
multi-mode
fiber
2km
2.5.4.
2.5.4.
2.5.4.
2.5.4. 2-port 100M Single-mode Optical Interface Module (DS-2FSM)
The DS-2FSM module provides 2 100M single-mode fast Ethernet optical interfaces. The physical
interface is a standard SC optical interface and the single-mode fiber is used whose maximum
transmission distance is 15 km. Two pairs of single-mode fibers are required for it. The fiber length
and peer interface type depend on the real situation.
1.1.1.20
1.1.1.20
1.1.1.20
1.1.1.20
Structure of the DS-2FSM module
The front panel of the DS-2FSM module is shown in the following figure: