Sagem 4450E User Manual
Page 121
SAGEM 3P@C
3P@C Installation Manual
Page 7-6 Reproduction and communication in any form prohibited without the written permission of
SAGEM SA
prompt
You must configure the terminal correctly.
Step 2: Start the equipment and enter the main menu of the Bootrom
Power on the equipment, and press
that you have accessed the Bootrom menu. The information of the menu is shown as follows:
3P@C 4450E Boot Loader V2.21
Compiled: Jan 3 2004 13:21:04
SDRAM test....passed.
Base ethernet MAC address: 00:05:3b:48:47:fd
? - List all available commands
h - List all available commands
g - Boot an executable image
dl - Enter download mode to load new image or config file
r - Reboot system
Press 'h' or '?' To get helping information.
3P@C:
For menu options and their meanings, see Figure 7-1.
prompt
You can upgrade the 3P@COS software in the Xmodem
mode. Alternatively, you can download new host program in
the FTP mode and save the program to Flash.
Step 3: Enter the download submenu
Select the No.
dl
option to enter the download mode as follows:
you enter download mode
? - List all available commands
h - List all available commands
n - Exchange load mode(default FTP)
p - Print boot parameters
c - Change boot parameters