SAGEM 3P@C
3P@C Installation Manual
Page 7-5 Reproduction and communication in any form prohibited without the written permission of
SAGEM SA
Item
Default
value
Description
the network port of the system control
board.
gateway inet(g) :
Need not be set
user(u)
The user name assigned to the FTP
server
ftp password (pw)
The assigned password corresponding
to the user name
flags(f) :
0x0
Need not be set
target name(tn) :
Need not be set
startup script(s) :
Need not be set
other(o) :
Need not be set
prompt
The black items must be set manually.
Step 5: Select the media of downloading the upgrade file
After modifying all parameters, select different command according to the type of the downloaded file. For
example, “a” indicates the program file of the system control board, and “da” indicates the ADU chipset code. For
details, see the description of download menu above.
Step 6: Return to the main menu
After completing the download, select the 18
th
option: x, to return to the main menu.
Step 7: Reboot
Select r in the main menu to reboot the system.
1.1.1.51.2 Upgrade the system software through the Console port
In this mode, the terminal needs to support the Xmode of sending files. Preferably, the baud rate can reach
115,200 to improve the download speed.
Step 1: Connect the cables
Connect the Console port of the system control board with the serial ports of the terminal through the cables
attached,
as shown in the figure below.
Figure 7-1 Connecting the console cables
Connect the console port
of the equipment
Connect the serial
port of the PC