To view the virtualization engine map, For internal use only – Sun Microsystems StorEdge 6900 Series User Manual
Page 97
Chapter 7
Troubleshooting Virtualization Engine Devices
81
For Internal Use Only
▼
To View the Virtualization Engine Map
The virtualization engine map is stored on the Storage Service Processor.
1. To view the virtualization engine map, type:
Note –
This example uses the virtualization engine map file, which could include
old information.
# showvemap -n v1 -f
VIRTUAL LUN SUMMARY
Disk pool
VLUN Serial
MP Drive
VLUN
VLUN
Size
Slic Zones
Number Target Target Name GB
---------------------------------------------------------------------------
t3b00 6257334B30303148 T49152 T16384 VDRV000 55.0
t3b00 6257334B30303149 T49152 T16385 VDRV001 55.0
*****
DISK POOL SUMMARY
Disk pool RAID MP Drive Size Free Space T3+ Active Number of
Target GB GB Path WWN VLUNs
-----------------------------------------------------------------------
t3b00 5 T49152 116.7 6.7 50020F2300006DFA 2
t3b01 5 T49153 116.7 116.7 50020F230000725B 0
*****
MULTIPATH DRIVE SUMMARY
Disk pool MP Drive T3+ Active Controller Serial
Target Path WWN Number
-------------------------------------------------------
t3b00 T49152 50020F2300006DFA 60020F2000006DFA
t3b01 T49153 50020F230000725B 60020F2000006DFA
*****
VIRTUALIZATION ENGINE SUMMARY
Initiator
UID
VE Host
Online
Revision
Number of SLIC Zones
--------------------------------------------------------------------------
I00001 2900006022004195 v1a Yes 08.14 0
I00002 2900006022004186 v1b Yes 08.14 0
*****
ZONE SUMMARY
Zone Name HBA WWN Initiator Online Number of VLUNs
---------------------------------------------------------------------
Undefined 210000E08B033401 I00001 Yes 0
Undefined 210000E08B026C0F I00002 Yes 0