T1/t2 fru tests available, For internal use only – Sun Microsystems StorEdge 6900 Series User Manual

Page 123

background image

Chapter 8

Troubleshooting the Sun StorEdge T3+ Array Devices

107

For Internal Use Only

T1/T2 FRU Tests Available

Switch -

switchtest

Link -

linktest

Running

linktest

from the Storage Automated Diagnostic Environment GUI

will guide the Service Engineer to discover the failed FRU.

Once the test has completed its run, an email message, similar to the following
message, will be sent to the Email recipient that was specified in

linktest

.

FIGURE 8-4

Example Link Test Text Output from the Storage Automated Diagnostic
Environment

running on diag.xxxxx.xxx.com

linktest started on FC interconnect: switch to switch

switchtest started on switch 100000c0dd00b682 port 8

Estimated test time 14 minute(s)

01/30/02 11:21:26 diag209 Storage Automated Diagnostic Environment: MSGID

6013 switchtest.FATAL

switch0: "Device: Switch Port: 8 is Offline"

switchtest failed

Remove FC Cable from switch: 100000c0dd00b682, port: 8

Insert FC loopback cable into switch: 100000c0dd00b682, port: 8

Continue Isolation ?

switchtest started on switch 100000c0dd00b682 port 8

Estimated test time 14 minute(s)

01/30/02 11:22:11 diag209 Storage Automated Diagnostic Environment: MSGID

6013 switchtest.FATAL

switch0: "Device: Switch Port: 8 is Offline"

switchtest failed

Remove FC loopback cable from switch: 100000c0dd00b682, port: 8

Insert a NEW FC GBIC into switch: 100000c0dd00b682, port: 8

Insert FC loopback cable into switch: 100000c0dd00b682, port: 8

Continue Isolation ?

switchtest started on switch 100000c0dd00b682 port 8

Estimated test time 14 minute(s)

01/30/02 11:25:12 diag209 Storage Automated Diagnostic Environment: MSGID

4001 switchtest.WARNING

switch0: "Maximum transfer size for a FABRIC port is 200. Changing transfer

size 2000 to 200"

switchtest completed successfully

Remove FC loopback cable from switch: 100000c0dd00b682, port: 8

Restore ORIGINAL FC Cable into switch: 100000c0dd00b682, port: 8

Suspect ORIGINAL FC GBIC in switch: 100000c0dd00b682, port: 8

Retest to verify FRU replacement.

linktest completed on FC interconnect: switch to switch