For internal use only – Sun Microsystems StorEdge 6900 Series User Manual
Page 83
Chapter 6
Troubleshooting Sun StorEdge FC Switch-8 and Switch-16 Devices
67
For Internal Use Only
switch
port
StateChange+
[ Info/Action ] port.1
in
SWITCH diag185
(
ip=
xxx.20.67.185
) is
now Available (status-
state changed from
OFFLINE to ONLINE)
Port on switch is
now available.
switch
port
StateChange-
Red
Y
[ Info/Action ] port.1
in
SWITCH diag185
(
ip=
xxx
.20.67.185
)
is now Not-Available
(status state changed
from ONLINE to
OFFLINE)
Information: A port
on the switch has
logged out of the
Fabric and has gone
offline.
Recommended
action:
1. Verify cables,
GBICs, and
connections
along the Fibre
Channel path.
2. Check Storage
Automated
Diagnostic
Environment
SAN Topology
GUI to identify
failing segment
of the data path.
3. Verify the correct
FC switch
configuration.
switch
enclosure
Statistics
[ Info ] Statistics
about
switch d2-
swb1
(ipxxx.0.0.41)
10002000007a609
Port Statistics
TABLE 6-1
Storage Automated Diagnostic Environment Event Grid for Switches (Continued)
Cat
Component
EventType
Sev
Action
Description
Information/Action