Virtualization Engine References

This Appendix contains the following Tables:

Table A-1 “SRN and SNMP Reference”

Table A-2 “SRN/SNMP Single Point of Failure Table”

Table A-3 “Port Communication”

Table A-4 “Service Codes”

TABLE A-1

provides an explanation of Service Request Numbers for the virtualization

engine.

TABLE A-1

SRN and SNMP Reference

SRN

Description

Corrective Action

1xxxx

Disk drive Check Condition status. xxxx is
the Unit Error Code.
The Unit Error Codes are returned by the
drive in Sense Data bytes 20-21 in response
to the SCSI Request Sense command.

If too many Check Conditions are returned,
then check the link status.

70000

SAN Configuration has changed.

70001

Rebuild process has started.

70002

Rebuild is completed without error.

70003

Rebuild is aborted with a read error.

This

means that the drive copying information
cannot read from the primary drive.

If a spare drive is available, it will be
brought in and used to replace the failed
drive. If no spare is available, replace the
failed drive with a new drive.

70004

Write error is reported by follower

. If the

initiator is master, then its follower has
detected a write error on a member within
a mirror drive.

If a spare drive is available, it will be
brought in and used to replace the failed
drive. If no spare is available, replace the
failed drive with a new drive.