beautypg.com

Telnet to affected sun storedge t3+ array, Re-enable the controller if possible (enable u), Replace the controller, if necessary – Sun Microsystems StorEdge 6900 Series User Manual

Page 135: Telnet to the affected sun storedge t3+ array, Replace the disk, if necessary, For internal use only

background image

Chapter 8

Troubleshooting the Sun StorEdge T3+ Array Devices

119

For Internal Use Only

t3

controller

State
Change-

Red

Y

[ Info/Action ]

controller.u1ctr

in

T3 diag213

(ip=xxx.

20.67.213

)

is now Not-Available
(status-state changed
from

unknown

to

ready-disabled

)

Information: The Sun
StorEdge T3+ array
controller has been
disabled.

Recommended action:

1. Telnet to affected

Sun StorEdge T3+
array.

2. Verify the

controller state
with ‘fru stat’ and
‘sys stat’.

3. Run ‘logger -

dmprstlog’ to
capture controller
information.

4. Re-enable the

controller if
possible (enable u)

5. Replace the

controller, if
necessary.

t3

disk

StateChange-

Red

Y

[ Info/Action ]

disk.u1d5

in T3

rasd3-t3b1

(ip=xxx.

0.0.41

) is

now Not-Available
(status-state changed
from

unknown

to

fault-disabled

).

Information: The Sun
StorEdge T3+ array
has reported that a
disk has failed.

Recommended action:

1. Telnet to the

affected Sun
StorEdge T3+ array

2. Verify that the disk

state is in

fru

stat

,

fru list

,

and

vol stat

.

3. Replace the disk, if

necessary.

Category

Component

EventType

Sev

Action

Description

Information

This manual is related to the following products: