Appendix A
Virtualization Engine References
127
7009A
Read degrade recorded
. A mirror drive
was written to, causing it to enter the
degrade state.
Reinsert the missing drive, or replace it
with a drive of equal or greater capacity.
7009B
Write degrade recorded
. If a spare drive is
available, it will be brought in and used to
replace the failed drive.
The removed drive needs to be (if good)
reinserted or (if bad) replaced.
7009C
Last primary failed during rebuild
. This is
a “multi-point failure” and is very rare.
• Backup drive data.
• Destroy mirror drive where failure has
occurred.
• Format (mode 14) drives.
• Create new mirror drive.
• Re-assign old SCSI ID and LUN to mirror
drive.
• Restore data.
71000
virtualization engine-to-virtualization
engine communication has recovered.
71001
This is a generic error code for the SLIC. It
signifies communication problems between
the virtualization engine and the Daemon.
Check the condition of the virtualization
engine.
Check the cabling between the
virtualization engine and Daemon server.
Error halt mode also forces this SRN.
71002
This indicates that the SLIC was busy.
Check the condition of the virtualization
engine.
Check the cabling between the
virtualization engine and the Daemon
server.
Error halt mode also forces this SRN.
71003
SLIC Master unreachable.
Check conditions of the virtualization
engines in the SAN.
71010
The status of the SLIC daemon has
changed.
72000
Primary/Secondary SLIC daemon
connection is active.
72001
Failed to read SAN drive configuration.
72002
Failed to lock on to SLIC daemon.
72003
Failed to read SAN SignOn Information.
72004
Failed to read Zone configuration.
TABLE A-1
SRN and SNMP Reference
SRN
Description
Corrective Action