Appendix A

Virtualization Engine References

127

7009A

Read degrade recorded

. A mirror drive

was written to, causing it to enter the
degrade state.

Reinsert the missing drive, or replace it
with a drive of equal or greater capacity.

7009B

Write degrade recorded

. If a spare drive is

available, it will be brought in and used to
replace the failed drive.

The removed drive needs to be (if good)
reinserted or (if bad) replaced.

7009C

Last primary failed during rebuild

. This is

a “multi-point failure” and is very rare.

• Backup drive data.
• Destroy mirror drive where failure has
occurred.
• Format (mode 14) drives.
• Create new mirror drive.
• Re-assign old SCSI ID and LUN to mirror
drive.
• Restore data.

71000

virtualization engine-to-virtualization
engine communication has recovered.

71001

This is a generic error code for the SLIC. It
signifies communication problems between
the virtualization engine and the Daemon.

Check the condition of the virtualization
engine.
Check the cabling between the
virtualization engine and Daemon server.
Error halt mode also forces this SRN.

71002

This indicates that the SLIC was busy.

Check the condition of the virtualization
engine.
Check the cabling between the
virtualization engine and the Daemon
server.
Error halt mode also forces this SRN.

71003

SLIC Master unreachable.

Check conditions of the virtualization
engines in the SAN.

71010

The status of the SLIC daemon has
changed.

72000

Primary/Secondary SLIC daemon
connection is active.

72001

Failed to read SAN drive configuration.

72002

Failed to lock on to SLIC daemon.

72003

Failed to read SAN SignOn Information.

72004

Failed to read Zone configuration.

TABLE A-1

SRN and SNMP Reference

SRN

Description

Corrective Action