Table b-2 – Sun Microsystems StorEdge 6900 Series User Manual
Page 151
Appendix B
SUNWsecfg Error Messages
135
TABLE B-2
Sun StorEdge Network FC Switch-8 and Switch-16 Switch SUNWsecfg Error Messages
Message
Description and Cause of Error
Suggested Action
Common Switch
Sun StorEdge system type entered,
${cab_type}
, does not match system
type discovered,
${boxtype
}.
Either call the command with the
-f force
option to force the series
type, or do not specify the cabinet type
(no
-c
option).
Common Switch
1. Unable to obtain lock on switch
${switch}
. Another command is
running.
1. Another switch command might be
updating the configuration. Check
listavailable -s
.
2. If the switch in question does not
appear, check for the existence of
the lock file directly by typing
ls
-la /opt/SUNWsecfg/etc
(look
for .
$switch.lock
).
3. If the lock is set in error, use the
removelocks -s
command to
clear it.
checkswitch
1. Current configuration on
$switch
does not match the defined
configuration.
2. One of the predefined static switch
configuration parameters, that can
be overridden for special
configurations such as NT connect
or cascaded switches, is set
incorrectly.
1. Select View Logs or directly view
$LOGFILE
for more details.
2. Re-run
setupswitch
on the
specified
$switch
.
listavailable
No Sun StorEdge network FC switch-8
or switch-16 switch devices are
available. They are either not found, or
the configuration lock is set.
Either the components (the Sun
StorEdge T3+ array, the switch, or the
virtualization engine) are down
(cannot be pinged) or another
SUNWsecfg
command is running and
is updating the configuration (
ps -ef
)
If no other commands are running and
you believe the configuration lock
might be set in error, run the
removelocks
command.