To verify the a2/b2 fc link, Fru tests available for a2/b2 fc link segment, To isolate the a2/b2 fc link – Sun Microsystems StorEdge 6900 Series User Manual
Page 49: For internal use only
Chapter 3
Troubleshooting the Fibre Channel Links
33
For Internal Use Only
Note –
You can find procedures for restoring virtualization engine settings in the
Sun StorEdge 3900 and 6900 Series Reference Manual.
▼
To Verify the A2/B2 FC Link
You can check the A2/B2 FC link using the Storage Automated Diagnostic
Environment, Diagnose—Test from Topology functionality. The Storage Automated
Diagnostic Environment’s implementation of diagnostic tests verifies the operation
of user-selected components. Using the Topology view, you can select specific tests,
subtests, and test options.
Refer to Chapter 5 of the Storage Automated Diagnostic Environment User’s Guide for
more information.
FRU Tests Available for A2/B2 FC Link Segment
■
The
linktest
is not available.
■
The switch and/or GBIC—
switchtest
test:
■
Can be used only in conjunction with the loopback connector.
■
Cannot be cabled to the virtualization engine while
switchtest
runs.
■
No virtualization engine tests are available at this time.
▼
To Isolate the A2/B2 FC Link
1. Quiesce the I/O on the A2/B2 FC link path.
2. Break the connection by uncabling the link.
3. Insert the loopback connector into the switch port.
4. Run
switchtest
:
a. If the test fails, replace the GBIC and rerun
switchtest
.
b. If the test fails again, replace the switch.