Sun StorEdge 3900 and 6900 Series Troubleshooting Guide • March 2002

70005

Write error is detected by master

.

If the initiator is master, then it has detected
a write error on a member within a mirror
drive.

If a spare drive is available, it will be
brought in and used to replace the failed
drive. If no spare is available, replace the
failed drive with a new drive.

70006

virtualization engine-to-virtualization
engine communication has failed.

Internal error. Update firmware.

70007

Rebuild is aborted with write error

. This

means the primary drive cannot write to
the drive being built.

If a spare drive is available, it will be
brought in and used to replace the failed
drive. If no spare is available, replace the
failed drive with a new drive.

70008

Read error is reported by follower

. If the

initiator is master, then its follower has
detected a read error on a member within a
mirror drive.

If a spare drive is available, it will be
brought in and used to replace the failed
drive. If no spare is available, replace the
failed drive with a new drive.

70009

Read error is detected by master

. If the

initiator is master, then it has detected a
read error on a member within a mirror
drive.

If a spare drive is available, it will be
brought in and used to replace the failed
drive. If no spare is available, replace the
failed drive with a new drive.

70010

CleanUp configuration table is completed.

70020

SAN physical configuration has changed.

If unintentional, check condition of drives.

70021

Drive is offline.

If unintentional, check condition of drives.

70022

virtualization engine is offline.

If unintentional, check condition of drives.

70023

Drive is unresponsive.

Check condition of drives.

70024

For Sun StorEdge T3+ array pack: Master
virtualization engine has detected the
partner virtualization engine’s IP Address.

70025

For Sun StorEdge T3+ array pack: Master
virtualization engine is unable to detect the
partner virtualization engine’s IP Address.

Check the Ethernet connection between the
two virtualization engines.

70030

SAN configuration changed by SV SAN
Builder.

70040

Host zoning configuration has changed.

70050

MultiPath drive Failover.

Check MultiPath drive.

70051

MultiPath drive Failback.

70098

Instant Copy degrade.

If no spare is available, replace the failed
drive with a new drive.

70099

Degrade because the drive has disappeared.

Reinsert the missing drive, or replace it
with a drive of equal or greater capacity.

TABLE A-1

SRN and SNMP Reference

SRN

Description

Corrective Action