Sun Microsystems StorEdge 6900 Series User Manual
Page 142
126
Sun StorEdge 3900 and 6900 Series Troubleshooting Guide • March 2002
70005
Write error is detected by master
.
If the initiator is master, then it has detected
a write error on a member within a mirror
drive.
If a spare drive is available, it will be
brought in and used to replace the failed
drive. If no spare is available, replace the
failed drive with a new drive.
70006
virtualization engine-to-virtualization
engine communication has failed.
Internal error. Update firmware.
70007
Rebuild is aborted with write error
. This
means the primary drive cannot write to
the drive being built.
If a spare drive is available, it will be
brought in and used to replace the failed
drive. If no spare is available, replace the
failed drive with a new drive.
70008
Read error is reported by follower
. If the
initiator is master, then its follower has
detected a read error on a member within a
mirror drive.
If a spare drive is available, it will be
brought in and used to replace the failed
drive. If no spare is available, replace the
failed drive with a new drive.
70009
Read error is detected by master
. If the
initiator is master, then it has detected a
read error on a member within a mirror
drive.
If a spare drive is available, it will be
brought in and used to replace the failed
drive. If no spare is available, replace the
failed drive with a new drive.
70010
CleanUp configuration table is completed.
70020
SAN physical configuration has changed.
If unintentional, check condition of drives.
70021
Drive is offline.
If unintentional, check condition of drives.
70022
virtualization engine is offline.
If unintentional, check condition of drives.
70023
Drive is unresponsive.
Check condition of drives.
70024
For Sun StorEdge T3+ array pack: Master
virtualization engine has detected the
partner virtualization engine’s IP Address.
70025
For Sun StorEdge T3+ array pack: Master
virtualization engine is unable to detect the
partner virtualization engine’s IP Address.
Check the Ethernet connection between the
two virtualization engines.
70030
SAN configuration changed by SV SAN
Builder.
70040
Host zoning configuration has changed.
70050
MultiPath drive Failover.
Check MultiPath drive.
70051
MultiPath drive Failback.
70098
Instant Copy degrade.
If no spare is available, replace the failed
drive with a new drive.
70099
Degrade because the drive has disappeared.
Reinsert the missing drive, or replace it
with a drive of equal or greater capacity.
TABLE A-1
SRN and SNMP Reference
SRN
Description
Corrective Action