Setupswitch exit values – Sun Microsystems StorEdge 6900 Series User Manual
Page 157
Appendix B
SUNWsecfg Error Messages
141
setupswitch Exit Values
lists the setupswitch exit values. The associated messages are logged in the
/var/adm/log/SEcfglog
log file.
TABLE 9-1
setupswitch
Exit Values
Severity
Level
Message Type
Message Meaning
0
INFO
All switch settings are properly set. The switch setting matches the default
configuration.
1
ERROR
Errors occurred while trying to set the proper switch settings.The switch
setting does not match the default configuration or any valid alternatives.
2
WARNING
Errors occurred while trying to set the proper switch settings. The ports did
not self-configure properly. A cable connection might not be working
properly. T ports self-configure (that is, the configuration tool cannot control
the configuration) from F ports when they are cabled properly. Specifically,
these are the ports on the back-end switches in Sun StorEdge 6900 series
configurations only. The ports support the ISL connections.
3
WARNING
The Flash code is different from the release level. The switch Flash code does
not match the current release version 30462.
This is not an error; QLogic periodically releases new versions of the switch
Flash code and the new version will not match the default version.
4
WARNING
The configuration is not set to the default, but the differences are likely
supported alternatives. The default switch configurations were overridden
with valid alternatives, which are also supported by the
SUNWsecfg
configuration tools. It should still be flagged as “not the default.” It can
imply any of the following alternatives (these messages are printed to the
screen and to the Storage Automated Diagnostic Environment GUI):
• INFO—Some ports have been set to SL mode, but should have been set
using the
setswitchs1
command. View and verify this nonstandard
configuration setup as required using the
showswitch
command. Refer to
the Sun StorEdge 3900 and 6900 Series Reference Manual for detailed
configuration information.
• INFO—The chassis ID on the switch is not set to the default value. This
could be caused by unique ID settings or by conflicts in a SAN environment.
• INFO—Ports are identified that are not in the default hard zone. This
could be because the port is set to the same hard zone as the cascaded
switch in a SAN environment.
NOTE:
If multiple solutions are connected to a switch, the switch settings might not match the default settings.