beautypg.com

For internal use only – Sun Microsystems StorEdge 6900 Series User Manual

Page 59

background image

Chapter 3

Troubleshooting the Fibre Channel Links

43

For Internal Use Only

To verify the failover

luxadm

display can be used, the failed path will be marked

OFFLINE, as shown in

CODE EXAMPLE 3-7

.

CODE EXAMPLE 3-7

Failed Path marked OFFLINE

Note –

This type of error may also cause the device to show up "unusable" in

cfgadm

, as shown in

CODE EXAMPLE 3-8

.

# luxadm display /dev/rdsk/c26t60020F200000644>

DEVICE PROPERTIES for disk: /dev/rdsk/

c26t60020F20000064433C3352A60003E82Fd0s2

Status(Port A): O.K.

Status(Port B): O.K.

Vendor: SUN

Product ID: T300

WWN(Node): 50020f2000006443

WWN(Port A): 50020f2300006355

WWN(Port B): 50020f2300006443

Revision: 0118

Serial Num: Unsupported

Unformatted capacity: 488642.000 MBytes

Write Cache: Enabled

Read Cache: Enabled

Minimum prefetch: 0x0

Maximum prefetch: 0x0

Device Type: Disk device

Path(s):

/dev/rdsk/c26t60020F20000064433C3352A60003E82Fd0s2

/devices/scsi_vhci/ssd@g60020f20000064433c3352a60003e82f:c,raw

Controller /devices/pci@a,2000/pci@2/SUNW,qlc@5/fp@0,0

Device Address 50020f2300006355,1

Class primary

State OFFLINE

Controller /devices/pci@e,2000/pci@2/SUNW,qlc@5/fp@0,0

Device Address 50020f2300006443,1

Class secondary

State ONLINE

This manual is related to the following products: