beautypg.com

Sun Microsystems StorEdge 6900 Series User Manual

Page 152

background image

136

Sun StorEdge 3900 and 6900 Series Troubleshooting Guide • March 2002

setswitchflash

Invalid flash file

$flashfile

.

Check the number of ports on switch

$switch

.

You might be attempting to download
a flash file for an 8-port switch to a 16-
port switch. Check

showswitch -s

$switch

and look for “number of

ports.” Ensure that this matches the
second and third characters of the flash
file name; for example: m08030462.fls.

setswitchflash

${switch}

timed out after reset. The

switch took longer than two minutes to
reset after a configuration change.

The switch might not be set for

rarp

,

or

rarp

is not working correctly. Try

ping $switch

after waiting a few

more minutes. If errors persist,
manually power cycle the switch.

setupswitch

Switch

${switch}

timed out after

reset.

The switch took longer than two
minutes to reset after a configuration
change. Try

ping $switch

after

waiting a few more minutes. If errors
persist, manually power cycle the
switch.

setupswitch

Could not set chassis ID on switch

${switch}

to

${cid}.

This should occur only in a SAN
environment with cascaded switches.
Be aware of the switch chassis IDs of
all switches in the SAN and make sure
the IDs are all unique. Once the chassis
IDs are established, override the switch
chassis IDs with the following
command:

setupswitch -s $switch_name -

i $unique_chassis_id -v

.

TABLE B-2

Sun StorEdge Network FC Switch-8 and Switch-16 Switch SUNWsecfg Error Messages

Message

Description and Cause of Error

Suggested Action

This manual is related to the following products: