Sun StorEdge 3900 and 6900 Series Troubleshooting Guide • March 2002
setswitchflash
Invalid flash file
$flashfile
.
Check the number of ports on switch
$switch
.
You might be attempting to download
a flash file for an 8-port switch to a 16-
port switch. Check
showswitch -s
$switch
and look for “number of
ports.” Ensure that this matches the
second and third characters of the flash
file name; for example: m08030462.fls.
setswitchflash
${switch}
timed out after reset. The
switch took longer than two minutes to
reset after a configuration change.
The switch might not be set for
rarp
,
or
rarp
is not working correctly. Try
ping $switch
after waiting a few
more minutes. If errors persist,
manually power cycle the switch.
setupswitch
Switch
${switch}
timed out after
reset.
The switch took longer than two
minutes to reset after a configuration
change. Try
ping $switch
after
waiting a few more minutes. If errors
persist, manually power cycle the
switch.
setupswitch
Could not set chassis ID on switch
${switch}
to
${cid}.
This should occur only in a SAN
environment with cascaded switches.
Be aware of the switch chassis IDs of
all switches in the SAN and make sure
the IDs are all unique. Once the chassis
IDs are established, override the switch
chassis IDs with the following
command:
setupswitch -s $switch_name -
i $unique_chassis_id -v
.
TABLE B-2
Sun StorEdge Network FC Switch-8 and Switch-16 Switch SUNWsecfg Error Messages
Message
Description and Cause of Error
Suggested Action