Chapter 2

General Troubleshooting Procedures

15

For Internal Use Only

Fibre Channel Links

The following sections provide troubleshooting information for the basic
components and Fibre Channel links, listed in

TABLE 2-1

.

Note –

In an actual Sun StorEdge 3900 or 6900 series configuration, there could be

more Sun StorEdge T3+ arrays than are shown in

FIGURE 2-1

and

FIGURE 2-2

.

By using the Storage Automated Diagnostic Environment, you should be able to
isolate the problem to one particular segment of the configuration.

The information found in this section is based on the assumption that the Storage
Automated Diagnostic Environment is running on the data host, and that it is
configured to monitor host errors. If the Storage Automated Diagnostic Environment
is not installed on the data host, there will be areas of limited monitoring, diagnosis
and isolation.

The following diagrams provide troubleshooting information for the basic
components and Fibre Channel links specific to the Sun StorEdge 3900 series, shown
in

FIGURE 2-1

, and the Sun StorEdge 6900 series, shown in

FIGURE 2-2

.

TABLE 2-1

Link

Provides Fibre Channel Link Between these Components

A1 to B1

Datahost, sw1a, and sw1b

A2

sw1a and v1a*

B2

sw1b and v1b*

A3

v1a and sw2a*

B3

v1b and sw2b*

A4

Master Sun StorEdge T3+ array and the “A” path switch

B4

AltMaster Sun StorEdge T3+ array and the “B” path switch

T1 to T2

sw2a and sw2b*

* Sun StorEdge 6900 series only