beautypg.com

Figure 3-2, Figure 3-3 – Sun Microsystems StorEdge 6900 Series User Manual

Page 40

background image

24

Sun StorEdge 3900 and 6900 Series Troubleshooting Guide • March 2002

FIGURE 3-2

Data Host Notification of Severe Link Error

FIGURE 3-3

Storage Service Processor Notification

Note –

An A1/B1 FC link error can cause a port in

sw1a

or

sw1b

to change state.

Site : FSDE LAB Broomfield CO

Source : diag.xxxxx.xxx.com

Severity : Normal

Category : Message Key: message:diag.xxxxx.xxx.com

EventType: LogEvent.driver.MPXIO_offline

EventTime: 01/08/2002 14:48:02

Found 2 ’driver.MPXIO_offline’ warning(s) in logfile: /var/adm/messages on

diag.xxxxx.xxx.com (id=80fee746):

Jan 8 14:47:07 WWN:2b000060220041f9 diag.xxxxx.xxx.com mpxio: [ID

779286 kern.info] /scsi_vhci/ssd@g29000060220041f96257354230303053

(ssd19) multipath status: degraded, path /pci@6,4000/SUNW,qlc@3/fp@0,0

(fp1) to target address: 2b000060220041f9,1 is offline

Jan 8 14:47:07 WWN:2b000060220041f9 diag.xxxxx.xxx.com mpxio: [ID

779286 kern.info] /scsi_vhci/ssd@g29000060220041f96257354230303052

(ssd18) multipath status: degraded, path /pci@6,4000/SUNW,qlc@3/fp@0,0

(fp1) to target address: 2b000060220041f9,0 is offline

Site : FSDE LAB Broomfield CO

Source : diag.xxxxx.xxx.com

Severity : Normal

Category : Switch Key: switch:100000c0dd0057bd

EventType: StateChangeEvent.X.port.6

EventTime: 01/08/2002 14:54:20

’port.6’ in SWITCH diag-sw1a (ip=192.168.0.30) is now Unknown (status-

state changed from ’Online’ to ’Admin’):

This manual is related to the following products: