Sun Microsystems StorEdge 6900 Series User Manual

Page 46

background image

30

Sun StorEdge 3900 and 6900 Series Troubleshooting Guide • March 2002

FIGURE 3-5

A2/B2 FC Link Storage Service Processor Side Event

Site : FSDE LAB Broomfield CO

Source : diag.xxxxx.xxx.com

Severity : Normal

Category : Switch Key: switch:100000c0dd0061bb

EventType: StateChangeEvent.X.port.1

EventTime: 01/08/2002 17:38:32

’port.1’ in SWITCH diag-sw1b (ip=192.168.0.31) is now Unknown (status-

state changed from ’Online’ to ’Admin’):

----------------------------------------------------------------

Site : FSDE LAB Broomfield CO

Source : diag.xxxxx.xxx.com

Severity : Normal

Category : San Key: switch:100000c0dd0061bb:1

EventType: LinkEvent.ITW.switch|ve

EventTime: 01/08/2002 17:39:47

ITW-ERROR (765 in 11 mins): Origin: port 1 on ’switch ’sw1b/192.168.0.31’.

Destination: port 1 on ve ’diag-v1b/29000060220041f4’:

Info:

An invalid transmission word (ITW) was detected between two components.

This could indicate a potential problem.

Cause:

Likely Causes are: GBIC, FC Cable and device optical connections.

Action:

To isolate further please run the Storage Automated Diagnostic Environment

tests associated with this link segment.