beautypg.com

Troubleshooting the t1/t2 data path, Notes – Sun Microsystems StorEdge 6900 Series User Manual

Page 118

background image

102

Sun StorEdge 3900 and 6900 Series Troubleshooting Guide • March 2002

Troubleshooting the T1/T2 Data Path

Notes

There are two T Port links for redundancy.

If one of the two links is lost, no Sun StorEdge T3+ array LUN failover will occur,
and no pathing failures will be noted.

If both T Port links fail, there will be a Sun StorEdge T3+ array LUN failover, as
one of the virtualization engines take control of the I/O operations. One of the
Sun StorEdge T3+ array LUNs will failover, as all I/O is routed to the controlling
virtualization engine.

The host will notice a pathing failure in its multipathing software.

This manual is related to the following products: