beautypg.com

Power led codes, Interpreting led service and diagnostic codes, For internal use only – Sun Microsystems StorEdge 6900 Series User Manual

Page 89

background image

Chapter 7

Troubleshooting Virtualization Engine Devices

73

For Internal Use Only

Power LED Codes

The virtualization engine LEDs are shown in

FIGURE 7-1

.

FIGURE 7-1

Virtualization Engine Front Panel LEDs

Interpreting LED Service and Diagnostic Codes

The Status LED communicates the status of the virtualization engine in decimal
numbers. Each decimal number is represented by number of blinks, followed by a
medium duration (two seconds) of LED off.

TABLE 7-2

lists the status LED code

descriptions.

The blink code repeats continuously, with a four-second off interval between code
sequences.

TABLE 7-2

LED Service and Diagnostic Codes

0

Fast blink

1

LED blinks once

2

LED blinks twice with one short duration (one second) between blinks

3

LED blinks three times with one short duration (one second) between blinks

...

10

LED blinks ten times with one short duration (one second) between blinks

This manual is related to the following products: