beautypg.com

Example – Sun Microsystems StorEdge 6900 Series User Manual

Page 116

background image

100

Sun StorEdge 3900 and 6900 Series Troubleshooting Guide • March 2002

Do not accept automatic emailing of the Explorer Data Collection Utility output,
unless the Storage Service Processor is properly set up to handle mail correctly.

Before running the Explorer Data Collection Utility, make sure that the switch and
Sun StorEdge T3+ array information is added to the proper

/opt/SUNWexplo/etc

files.

Example

1. Type switch information into the

/opt/SUNWexplo/etc/saninput.txt

file.

Edit the file with a text editor such as vi.

CODE EXAMPLE 8-1

Editing switch information using

vi

2. Type Sun StorEdge T3+ array information into the

/opt/SUNWexplo/etc/

t3input.txt

file. Edit the file with a text editor such as

vi

.

3. Type the password for your specific site.

Automatic Email Submission

Would you like all explorer output to be sent to:

[email protected]

at the completion of explorer when -mail or -e is specified?

[y,n] n

# vi saninput.txt

# Input file for extended data collection

# Format is SWITCH SWITCH-TYPE PASSWORD LOGIN

# Valid switch types are ancor and brocade

# LOGIN is required for brocade switches, the default is admin

sw1a ancor

sw1b ancor

sw2a ancor

sw2b ancor

:wq!

This manual is related to the following products: