beautypg.com

Code example 4-1 – Sun Microsystems StorEdge 6900 Series User Manual

Page 64

background image

48

Sun StorEdge 3900 and 6900 Series Troubleshooting Guide — March 2002

Note –

For cluster configurations and systems that are attached to Windows NT, the

default configurations may not match the current installed configuration. Be aware
of this when running the verification scripts. Certain items may be flagged as FAIL
in these special circumstances.

CODE EXAMPLE 4-1

/opt/SUNWsecfg/checkdefaultconfig

output

# /opt/SUNWsecfg/checkdefaultconfig

Checking all accessible components.....

Checking switch: sw1a

Switch sw1a - PASSED

Checking switch: sw1b

Switch sw1b - PASSED

Checking switch: sw2a

Switch sw2a - PASSED

Checking switch: sw2b

Switch sw2b - PASSED

Please enter the Sun StorEdge T3+ array password :

Checking T3+: t3b0

Checking : t3b0 Configuration.......

Checking command ver : PASS

Checking command vol stat : PASS

Checking command port list : PASS

Checking command port listmap : PASS

Checking command sys list

:

FAIL

<-- Failure Noted

Checking T3+: t3b2

Checking : t3b2 Configuration.......

Checking command ver : PASS

Checking command vol stat : PASS

Checking command port list : PASS

Checking command port listmap : PASS

Checking command sys list : PASS

Checking Virtualization Engine Pair Parameters: v1a

v1a configuration check passed

Checking Virtualization Engine Pair Parameters: v1b

v1b configuration check passed

Checking Virtualization Engine Pair Configuration: v1

checkvemap: virtualization engine map v1 verification complete: PASS.

This manual is related to the following products: