Sun Microsystems StorEdge 6900 Series User Manual
Page 146
130
Sun StorEdge 3900 and 6900 Series Troubleshooting Guide • March 2002
54
Unauthorized cabling configuration.
• Check cabling.
57
Too many HBAs attempting to log in.
• Check cabling.
60
Node mapping table cleared using SW2.
• No action required.
62
Improper SW2 setting.
• Correct SW2 setting.
• Cycle virtualization engine power.
126
Too many virtualization engines in SAN.
• Remove the extra virtualization engine.
• Cycle virtualization engine power.
130
Heartbeat connection between
virtualization engines is down.
• Correct problem.
• Cycle the power on the follower
virtualization engine.
400 - 599 Device side interface driver errors:
409
FC device-side type code invalid.
• Cycle power
• If problem persists, replace virtualization
engine.
434
Too many elastic store errors to continue.
Elastic store errors result from a clock
mismatch between transmitter and receiver
and indicates an unreliable link. This error
can also occur if a device in the SAN loses
power unexpectedly.
• Check for faulty component and replace.
• Cycle the power on the follower
virtualization engine.
TABLE A-4
Service Codes