beautypg.com

Sun Microsystems StorEdge 6900 Series User Manual

Page 146

background image

130

Sun StorEdge 3900 and 6900 Series Troubleshooting Guide • March 2002

54

Unauthorized cabling configuration.

• Check cabling.

57

Too many HBAs attempting to log in.

• Check cabling.

60

Node mapping table cleared using SW2.

• No action required.

62

Improper SW2 setting.

• Correct SW2 setting.
• Cycle virtualization engine power.

126

Too many virtualization engines in SAN.

• Remove the extra virtualization engine.
• Cycle virtualization engine power.

130

Heartbeat connection between
virtualization engines is down.

• Correct problem.
• Cycle the power on the follower
virtualization engine.

400 - 599 Device side interface driver errors:

409

FC device-side type code invalid.

• Cycle power
• If problem persists, replace virtualization
engine.

434

Too many elastic store errors to continue.
Elastic store errors result from a clock
mismatch between transmitter and receiver
and indicates an unreliable link. This error
can also occur if a device in the SAN loses
power unexpectedly.

• Check for faulty component and replace.
• Cycle the power on the follower
virtualization engine.

TABLE A-4

Service Codes

This manual is related to the following products: