Appendix B
SUNWsecfg Error Messages
133
Common to
virtualization engine
1. Device-side operating mode is not
set properly.
2. Device-side UID reporting scheme
is not set properly.
3. Host-side operating mode is not set
properly.
4. Host-side LUN mapping mode is
not set properly.
5. Host-side Command Queue Depth
is not set properly.
6. Host-side UID distinguish is not set
properly.
7. IP is not set properly.
8. Subnet mask is not set properly.
9. Default gateway is not set properly.
10. Server port number is not set
properly.
11. Host WWN Authentications are not
set properly.
12. Host IP Authentications are not set
properly.
13. Other VEHOST IP is not set
properly.
Log in to the virtualization engine and
verify that the device, host, and
network settings are correct. Make sure
the virtualization engine hardware is
not in ERROR 50 mode. If required,
power cycle the virtualization engine
hardware, or disable the host-side
switch port. Run the
setupve -n
ve_name
command and enable the
switch port.
checkslicd
Cannot establish communication with
${vepair}
.
Run
startslicd -n ${vepair}
.
checkslicd
Cannot establish communication with
virtualization engine pair
${vepair}
initiator
{$initiator}
.
Determine the host name associated
with
${initiator}
by using the
showvemap -n ${vepair} -f
command output. Run the command
r
esetve -n vename
.
checkvemap
Cannot establish communication with
${vepair}
Run the command again. If this fails,
check the status of both virtualization
engines. If there is an error condition,
see Appendix A for corrective action.
TABLE B-1
Virtualization Engine SUNWsecfg Error Messages (Continued)
Message
Description and Cause of Error
Suggested Action