Fru tests available for a1/b1 fc link segment – Sun Microsystems StorEdge 6900 Series User Manual
Page 42
26
Sun StorEdge 3900 and 6900 Series Troubleshooting Guide • March 2002
An error in the A1/B1 FC link can also cause a device to enter the “unusable” state
in
cfgadm
. In this case, the output for
luxadm -e port
will show that a device that
was “connected” changed to an “unconnected” state.
CODE EXAMPLE 3-2
cfgadm -al Display
FRU Tests Available for A1/B1 FC Link Segment
■
HBA—
qlctest
(1M)
■
A
vailable only if the Storage Automated Diagnostic Environment is installed
on a data host
■
C
auses HBA to go “offline” and “online” during tests
■
Switch —
switchtest
(1M)
■
C
an be run while the link is still cabled and online (connected to HBA)
■
You must specify a payload of 200 bytes or less when testing the A1/B1 FC
link, while the link is connected to the HBA (limitation in HBA ASIC).
■
Can be run only from the Storage Service Processor
■
The
dev
option to
switchtest
is in the following format:
Port:IP-Address:FCAddress
The
FCAddress
can be set to 0x0
...
# cfgadm -al
Ap_Id
Type
Receptacle
Occupant
Condition
c0
scsi-bus
connected
configured
unknown
c0::dsk/c0t0d0
disk
connected
configured
unknown
c0::dsk/c0t1d0
disk
connected
configured
unknown
c1
scsi-bus
connected
configured
unknown
c1::dsk/c1t6d0
CD-ROM
connected
configured
unknown
c2
fc-fabric
connected
configured
unknown
c2::210100e08b23fa25
unknown
connected
unconfigured unknown
c2::2b000060220041f4
disk
connected
configured
unknown
c3
fc-fabric
connected
configured
unknown
c3::2b000060220041f9
disk
connected
configured
unusable
c4
fc-private
connected
unconfigured unknown
c5
fc