beautypg.com

Fru tests available for a1/b1 fc link segment – Sun Microsystems StorEdge 6900 Series User Manual

Page 42

background image

26

Sun StorEdge 3900 and 6900 Series Troubleshooting Guide • March 2002

An error in the A1/B1 FC link can also cause a device to enter the “unusable” state
in

cfgadm

. In this case, the output for

luxadm -e port

will show that a device that

was “connected” changed to an “unconnected” state.

CODE EXAMPLE 3-2

cfgadm -al Display

FRU Tests Available for A1/B1 FC Link Segment

HBA—

qlctest

(1M)

A

vailable only if the Storage Automated Diagnostic Environment is installed

on a data host

C

auses HBA to go “offline” and “online” during tests

Switch —

switchtest

(1M)

C

an be run while the link is still cabled and online (connected to HBA)

You must specify a payload of 200 bytes or less when testing the A1/B1 FC
link, while the link is connected to the HBA (limitation in HBA ASIC).

Can be run only from the Storage Service Processor

The

dev

option to

switchtest

is in the following format:

Port:IP-Address:FCAddress

The

FCAddress

can be set to 0x0

...

# cfgadm -al

Ap_Id

Type

Receptacle

Occupant

Condition

c0

scsi-bus

connected

configured

unknown

c0::dsk/c0t0d0

disk

connected

configured

unknown

c0::dsk/c0t1d0

disk

connected

configured

unknown

c1

scsi-bus

connected

configured

unknown

c1::dsk/c1t6d0

CD-ROM

connected

configured

unknown

c2

fc-fabric

connected

configured

unknown

c2::210100e08b23fa25

unknown

connected

unconfigured unknown

c2::2b000060220041f4

disk

connected

configured

unknown

c3

fc-fabric

connected

configured

unknown

c3::2b000060220041f9

disk

connected

configured

unusable

c4

fc-private

connected

unconfigured unknown

c5

fc

connected

unconfigured unknown

This manual is related to the following products: