Sun StorEdge 3900 and 6900 Series Troubleshooting Guide — March 2002
lists the Virtualization Engine Events.
TABLE 7-5
Storage Automated Diagnostic Environment Event Grid for Virtualization Engine
Category
Component
EventType
Sev
Action
Description
virtualization
engine
enclosure
Alarm
Yellow
Volume E00012 on
v1a changed
mapping.
virtualization
engine
enclosure
Alarm.log
Yellow
Change in Port
Statistics on
virtualization
engine v1a
virtualization
engine
enclosure
Audit
[ Info ] Auditing a
Virtualization
Engine called v1a
Information:
Audits occur every
week and send a
detailed description of
the enclosure to the
Sun Network Storage
Command Center
(NSCC)
virtualization
engine
oob
Comm_
Established
Communication
regained with
virtualization
engine v1a
virtualization
engine
oob
Comm_
Lost
Down
Y
[ Info/Action ]
Lost
communication
with virtualization
engine v1a
Information:
Ethernet connectivity
to the virtualization
engine unit has been
lost.
Recommended action:
1. Check Ethernet
connectivity to the
virtualization
engine.
2. Make sure the
virtualization
engine is boosted
correctly.
3. Verify that the
TCP/IP settings on
the virtualization
engine are correct.
4. Replace the
virtualization
engine if necessary.