beautypg.com

For internal use only – Sun Microsystems StorEdge 6900 Series User Manual

Page 81

background image

Chapter 6

Troubleshooting Sun StorEdge FC Switch-8 and Switch-16 Devices

65

For Internal Use Only

switch

enclosure

Audit

Auditing a new
switch called

ras

d2-swb1

(ip=xxx.0.0.41)

10002000007a609

switch

oob

Comm_
Established

Communication
regained with

sw1a

(ip=

xxx.

20.67.213)

switch

oob

Comm_Lost

Down

Yes

[ Info/Action ] Lost

communication with
sw1a
(ip=xxx.20.67.213)

Information:
Ethernet
connectivity to the
switch has been lost.

Recommended
action:
1. Check Ethernet

connectivity to
the switch.

2. Verify that the

switch is booted
correctly with no
POST errors.

3. Verify that the

switch Test Mode
is set for normal
operations.

4. Verify the TCP/

IP settings on
switch via Forced
PROM Mode
access.

5. Replace switch, if

needed.

switch

switchtest

Diagnostic
Test-

Red

switchtest (diag240)
on d2-swb1
(ip=xxx.0.0.41)
10002000007a609

TABLE 6-1

Storage Automated Diagnostic Environment Event Grid for Switches (Continued)

Cat

Component

EventType

Sev

Action

Description

Information/Action

This manual is related to the following products: