Sun StorEdge 3900 and 6900 Series Troubleshooting Guide • March 2002
1. Discover the error by checking one or more of the following messages or files:
■
Storage Automated Diagnostic Environment alerts or email messages
■
/var/adm/
messages
■
Sun StorEdge T3+ array
syslog
file
■
Storage Service Processor messages
■
/var/adm/messages.t3
messages
■
/var/adm/log/SEcfglog
file
2. Determine the extent of the problem by using one or more of the following
methods:
■
Storage Automated Diagnostic Environment Topology view
■
Storage Automated Diagnostic Environment Revision Checking (manual patch or
package, to check whether the package or patch is installed)
■
Verify the functionality using one of the following:
■
checkdefaultconfig
(1M)
■
checkt3config
(1M)
■
cfgadm -al
output
■
luxadm
(1M) output
■
Check the multipathing status using the Sun StorEdge Traffic Manager software
or
VxDMP
.
3. Check the status of a Sun StorEdge T3+ array by using one or more of the
following methods:
■
Storage Automated Diagnostic Environment device monitoring reports
■
Run the
SEcfg
script, which displays and shows the Sun StorEdge T3+ array
configuration
■
Manually open a telnet session to the Sun StorEdge T3+ array
■
luxadm
(1M) display output
■
LED status on the Sun StorEdge T3+ array
■
Explorer Data Collection Utility output (located on the Storage Service Processor)