beautypg.com

Chapter 8 – auto dial-in feature, Introduction, Prerequisites – Multi-Tech Systems MTS2SA-T User Manual

Page 73: Mandatory configuration settings, Optional configuration settings

background image

Chapter 8 – Auto Dial-in Feature

Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A)

73

Chapter 8 – Auto Dial-in Feature

Introduction

The auto dial-in feature enables the MultiConnect IP to act as a Telnet client thus facilitating the serial
device to access any Telnet/terminal servers on the IP network (over the built-in modem interface). Once
the session (Serial Client to Server) is opened successfully, it allows two-way traffic between the serial
device and the remote server.

The MultiConnect IP, acting as a Telnet/RAW-TCP client, accommodates the following features when
configured:

Support to open the session using Telnet client (residing in the MultiConnect IP) in Telnet Mode or
RAW Mode.

Support to open the session to the specified port from a Serial Command prompt (Manual Dial-in).

Switching between a Command prompt and a Dial-in session when the session is in Telnet mode.

Support to open the session to the configured port directly (Serial Auto Dial-in) whenever the serial
port is free.

Prerequisites

Mandatory Configuration Settings

The following items must be configured in order to use the dial-in feature

:

Enable Auto dial-in globally on all the serial ports.

# set serial auto-telnet enable

Enable Auto dial-in on the serial port S0.

# set serial s0 auto-dial-in enable

Set the Auto dial-in protocol.

# set serial s0 auto-dialin-protocol telnet

Set the Auto dial-in Server IP Address.

# set serial s0 auto-dialin-ipaddress

Set the port to the one, which the Telnet client will be connected.

# set serial s0 auto-dialin-port

An ERROR message will display if any of the above details are not configured or not valid.

Optional Configuration Settings

The following commands can be used for optional configurations:

Enable/Disable Switching-between-Dial-in and the Command Prompt feature.

# set serial escape-monitor

Set the Escape-Monitor-String to switch between Dial-in and Command Prompt sessions.

# set serial escape-string "+++inet"

Set the Serial Dial-in Trigger mode. It dictates the criterion for establishing a connection.
The options provided are on reception of .
Refer to the command line configuration section for details about this command.

# set serial s0 auto-dialin trig-mode

Enable/Disable the RAW mode globally for all Auto-Dial-in sessions.

# set ip telnet raw-mode

Enable/Disable the RAW mode for Auto-Dial-in session on serial port S0.

# set serial s0 raw-dial-in

This manual is related to the following products: