beautypg.com

Setup and configuration prerequisites – Multi-Tech Systems MTS2SA-T User Manual

Page 144

background image

Chapter 13 – SMTP Client

Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A)

144

Setup and Configuration Prerequisites

The following details are mandatory for configuration and have to be validated before sending an email:

• Host Interaction Mode enabled to restrict Telnet-Dialout and PPP.
Command:

set serial host-interaction-mode enable

• Set SMTP server name or IP address of maximum length 64 characters.
Command:

set send-mail smtp-server-name

• Set SMTP server port.
Command:

set send-mail smtp-server-port <25>

Set Host name of maximum length 64 characters.
Command: set send-mail host-name

Set From address identity of maximum length 64 characters.
Command: set send-mail from-address-identity

Set From address of maximum length 64 characters.
Command: set send-mail from-address

Notes:

1.

The send-mail command prompts for the ERROR message if any of the above details

are not configured or not valid.

2.

The following configuration suggestions are optional:

Set reply-to address of maximum length 64 characters. By default the server takes
the from address as the reply-to-address.

If this is configured, this address is taken as the reply to address.
set send-mail reply-to-address

This manual is related to the following products: