beautypg.com

Multi-Tech Systems MTS2SA-T User Manual

Page 107

background image

Chapter 10

− Modem Mode AT Commands, S-Registers, and Result Codes

Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A)

107


Command:

+MS Modulation

Selection

Description:

This extended-format compound parameter controls the manner of operation of the
modulation capabilities in the modem. It accepts six subparameters.

Table 8-1. +MS Command Supported Rates

Modulation

Possible (, , (),

and ) Rates (bps)

Bell 103

B103

300

Bell 212

B212

1200 Rx/75 Tx or 75 Rx/1200 Tx

V.21 V21

300

V.22 V22

1200

V.22 bis

V22B

2400 or 1200

V.23 V23C

1200

V.32

V32

9600 or 4800

V.32 bis

V32B

14400, 12000, 9600, 7200, or 4800

V.34

V34

33600, 31200, 28800, 26400, 24000, 21600, 19200, 16800,
14400, 12000, 9600, 7200, 4800, or 2400

56K

K56

56000, 54000, 52000, 50000, 48000, 46000, 44000, 42000,
40000, 38000, 36000, 34000, 32000

V.90

V90

56000, 54667, 53333, 52000, 50667, 49333, 48000, 46667,
45333, 44000, 42667, 41333, 40000, 38667, 37333, 36000,
34667, 33333, 32000, 30667, 29333, 28000

V.92
downstream

V92

56000, 54667, 53333, 52000, 50667, 49333, 48000, 46667,
45333, 44000, 42667, 41333, 40000, 38667, 37333, 36000,
34667, 33333, 32000, 30667, 29333, 28000

V.92
upstream

V92

48000, 46667, 45333, 44000, 42667, 41333, 40000, 38667,
37333, 36000, 34667, 33333, 32000, 30667, 29333, 28000,
26667, 25333, 24000

Note:

Some values may not be supported by certain model models. For

example, modem models supporting V92 may not support K56.

Defined Values:

A string that specifies the preferred modem carrier to use in originating or
answering a connection. values are strings of up to eight
characters, consisting only of numeric digits and upper case letters.
values for ITU standard modulations take the form: <1-4
digits>. Defined values are listed in Table 8-1.

A numeric value which enables or disables automatic modulation negotiation

(ITU-T V.32bis Annex A or V.8).

0 = Automode disabled.

1 = Automode enabled. (Default.)

and

Numeric values which specify the lowest () and highest
() rate at which the modem may establish a receive
connection. May be used to condition distinct limits for the receive direction
as distinct from the transmit direction. Values for this subparameter are
decimal encoded, in units of bit/s. The possible values for each modulation
are listed in Table 8-1. Actual values will be limited to possible values
corresponding to the entered and fall-back as determined
during operation. (Default = lowest () and highest
() rate supported by the selected carrier.)

and

Numeric values which specify the lowest () and highest
() rate at which the modem may establish a transmit
connection. Non-zero values for this subparameter are decimal encoded, in
units of bit/s. The possible values for each modulation are listed in Table 8-3.
Actual values will be limited to possible values corresponding to the entered
and fall-back as determined during operation. (Default =
lowest () and highest () rate supported by the
selected carrier.)

Reporting Current or Selected Values

Command: +MS?
Reporting Supported Range of Parameter Values
Command: +MS=?

Result Code:

OK - Valid subparameter string

Otherwise ERROR

This manual is related to the following products: