Multi-Tech Systems MTS2SA-T User Manual
Page 43

Chapter 4 – Command Line Interface (CLI)
Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A)
43
PPP Commands – Setup
Command Syntax
set ppp
Description
Configures the maximum number of dialing retries.
Maximum dialing retry is 100
Default Value
5
Success
OK
Error
1. Too few arguments
“Usage: set ppp ppp0 dialing-max-retires [0-100](times)
Type ‘set ppp ppp0 dialing-max-retries ?’ for more information”
2. Multiple matches
dialing-max-retries and dialing-retry-interval
3. Retry range
“error: dialing-max-retries range : [0 - 100]
Type ‘set ppp ppp0 dialing-retry-interval ?’ for more information”
Command Syntax
set ppp
Description
Configures the interval for the port to retry dialing.
Maximum dialing retry is 300.
Default Value
15
Success
OK
Error
1. Too few arguments
“Usage: set ppp ppp0 dialing-retry-interval [0-300](secs)
Type ‘set ppp ppp0 dialing-retry-interval ?’ for more information”
2. Multiple matches
dialing-max-retries and dialing-retry-interval
3. Retry range
“error: dialing-retry-interval range : [0 - 300]
Type ‘set ppp ppp0 dialing-retry-interval ?’ for more information”
Command Syntax
set ppp
Description
Configures the dial-on-demand idle timeout value .Maximum dialing retry is
900 secs
Default Value
600 secs
Success
OK
Error
1. Too few arguments
“Usage: set ppp ppp0 idle-timeout <0-900>
Type set ppp ppp0 idle-timeout ?’ for more information”
2 Idle timeout range
“error: dod-idle-timeout range : [0 - 900]
Type ‘set ppp ppp0 idle-timeout ?’ for more information”
Command Syntax
set ppp
Description
Sets the IPCP mode-to-client-only or client or LAN.
Default Value
client-only
Success
OK
Error
1. Too few arguments
Possible
argument(s)
are
client-only and client-or-lan
2. Invalid string
Invalid argument.
Valid argument(s) are client-only and client-or-lan