Notes for AT#UD Tables

1.

The modem may insert a delay (e.g., 10 ms) between information text lines.

2.

The code tables include values for data and fax calls. Some of the codes are

applicable only to data calls (e.g., data compression), some to call origination (e.g., busy,
answering signal detection), and some to the answering modem (e.g., calling signal detection).

3.

callCleared codes from 3.6.4/V.58-1994 –

callCleared: indicates that the DCE has gone on-

hook and that the previously existing network connection has been cleared. These values are
hex values, converted from decimal in V.58. callCleared codes are described in Table 8-10.

Table 8-2. AT#UD Last Call Status Report Format
Key

Value(s)

Definition

0

2 digits

Diagnostic Command Specification revision number, digit.digit

1

Table 8-3

Call Setup Result code

2

Table 8-4

Multi-media mode

3

Table 8-5

DTE-DCE interface mode

4

String

V.8 CM octet string, same format as V.250, in quotes

5

String

V.8 JM octet string, same format as V.250, in quotes

10

0-2F

Received signal power level, in –dBm (0-43)

11

0-1F

Transmit signal power level, in –dBm (e.g., 0-17)

12

0-64

Estimated noise level, in –dBm (e.g., 10-90)

17

0-FFF

Round Trip delay, in units of ms

18

Table 8-6

V.34 INFO bit map

20

Table 8-7

Transmit Carrier Negotiation Result

21

Table 8-7

Receive Carrier Negotiation Result

22

0-1F40

Transmit Carrier symbol rate (0-8000) in symbol/s

23

0-1F40

Receive Carrier symbol rate (0-8000) in symbol/s

24

0-FA0

Transmit Carrier frequency (0-4000) in Hz

25

0-FA0

Receive Carrier frequency (0-4000) in Hz

26

0-FA00

Initial transmit carrier data rate (0-64000) in bit/s

27

0-FA00

Initial receive carrier data rate (0-64000) in bit/s

30

0-FF

Temporary carrier loss event count

31

0-FF

Carrier Rate re-negotiation event count

32

0-FF

Carrier Retrains requested

33

0-FF

Carrier Retrain requests granted

34

0-FA00

Final transmit carrier data rate in bit/s

35

0-FA00

Final receive carrier data rate in bit/s

40

Table 8-8

Protocol Negotiation Result

41

0-400

Error Control frame size in bytes

42

0-FF

Error control link timeouts in transmission

43

0-FF Error

control link NAKs received

44

Table 8-9

Compression Negotiation Result

50

0-2

Transmit flow control: 0=off; 1=DC1/DC3; 2=V.24 circuit 106/133

51

0-2

Receive flow control: 0=off; 1=DC1/DC3; 2=V.24 circuit 106/133

52

0-FFFFFFFF Transmit characters sent from DTE

53

0-FFFFFFFF Received characters sent to DTE

54

0-FFFF

Transmit characters lost (data overrun errors from DTE)

55

0-FFFF

Received characters lost (data overrun errors to DTE)

56

0-FFFFFFFF Transmit I- Frame count, if error control protocol running

57

0-FFFFFFFF Received I-Frame count, if error control protocol running

58

0-FFFF

Transmit I-Frame error count, if error control protocol running

59

0-FFFF

Received I- Frame error count, if error control protocol running

60

Table 8-10

Termination Cause

61

0-FF Call

Waiting event count

Table 8-3. Call Setup Result Codes
Code

Definition

0

No previous call (modem log has been cleared since any previous calls)

1

No dial tone detected

2

Reorder signal detected, network busy

3

Busy signal detected

4

No recognized signal detected (e.g., no signal, or nothing recognizable)

5

Voice detected * if this is a voice modem (V.253) in voice mode

7

Data Answering signal detected (e.g., V.25 ANS, V.8 ANSam)

8

Data Calling signal detected (e.g., V.25 CT, V.8 CI)

9

Fax Answering signal detected (e.g., T.30 CED, DIS)

A

Fax Calling signal detected (e.g., T.30 CNG)

B

V.8bis signal detected