Chapter 4 – Command Line Interface (CLI)

Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A)

24

IP Commands – Setup

Command Syntax

set ip syslogd-server

Description

Sets the remote syslog server's IP address.

Default Value

0.0.0.0

Success

OK

Error

1. Too few arguments

“Usage: set ip syslogd-server

Type ‘set ip syslogd-server ?’ for more information”
2. Invalid

IP

address

“error: Invalid IP address

Type ‘set ip syslogd-server ?’ for more information”

Command Syntax

set ip tcp-keepalive

Description

Sets the TCP keep-alive timeout for the MultiConnect IP.
't' : range from 3-120 minutes

Default Value

3 minutes

Success

OK

Error

1. Too few arguments

“Usage: set ip tcp-keepalive

Type ‘set ip tcp-keepalive ?’ for more information”
2. Invalid

IP

address

“error: Invalid value, rante [3-120] mins

Type ‘set ip tcp-keepalive ?’ for more information”


Command Syntax

set ip telnet

Description

Enables/disables the Telnet Server. This is a global setting, which will
enable/disable the Telnet Server in the MultiConnect IP.

Note:

Upon disabling Telnet server, the administrator cannot configure the

MultiConnect IP over the built-in Modem interface (wherein PPP has
acquired IP Address). The only option is to connect through a terminal
application over the Serial port.

Default Value

Enabled

Success

OK

Error

1. Too few arguments

Too few arguments. Possible argument(s) are

set ip telnet

Type : set ip telnet ? for more information)

2. Multiple matches

telnet
telnet-port

3. Invalid String

Invalid argument "invalid string"

Valid arguments are

auto-dialout escape-string
inactivity inactivity-timeout
escape-monitor raw-mode

Possible

value(s)

are

enable or disable

This manual is related to the following products: