SNTP Client Commands – Setup

Command Syntax

set sntp-client daylight-saving end-weekday
where

dayofweek = Sunday, Monday … Saturday

Description

Sets the end weekday to use during the Day Light Saving Mode.

Default Value

Sunday

Success

OK

Error

2.

Invalid arguments

„error: Invalid end day of the week“

2.

Too few arguments

“Usage: set sntp-client daylight-saving end-weekday
Type set sntp-client daylight-saving end-weekday ? for more
information”

Command Syntax

set sntp-client daylight-saving end-month
where
month = january, …december

Description

Sets the end month to use during the Day Light Saving Mode.

Default Value

October

Success

OK

Error

2.

Invalid arguments

„error: Invalid end month“

2.

Too few arguments

“Usage: set sntp-client daylight-saving end-month
Type set sntp-client daylight-saving end-month ? for more information”

Command Syntax

set sntp-client daylight-saving end-time
where
hh = 00 to 23
mm = 00 to 59

Description

Sets the end time to use during the Day Light Saving Mode.

Default Value

02:00

Success

OK

Error

2.

Invalid arguments

„error: Invalid end time“

2.

Too few arguments

“Usage: set sntp-client daylight-saving end-time
Type set sntp-client daylight-saving end-time ? for more information”

SNTP Client Commands – Show

Command Syntax

show sntp configuration

Description

Displays the SNTP configuration

Default Value

NA

Success

OK

Error

1. Too few arguments

Possible value(s) are configuration