beautypg.com

Intel® management module (imm) features, Professional edition features, Intel – Gateway 9715 User Manual

Page 51: Management module (imm) features

background image

46

www.gateway.com

Chapter 3: Managing and Maintaining Your Server

SDR/SEL timestamp clock

Board set FRU information interface

Fault resilient booting

System management watchdog timer

Front panel system diagnostic-interrupt handling

Platform Management Interruption (PMI) / System Diagnostic Interrupt (SDI) status
monitor

Event receiver

System interface to the IPMB (via system interface ports)

IPMI Management Controller Initialization Agent (MCIA)

Emergency Management Port (EMP) interface

Serial/modem and LAN alerting

In this server, the BMC is also the chassis bridge controller, providing integrated ICMB
support. ICMB transports server management information between chassis in a cluster
configuration that can contain multiple servers and peripherals.

Intel

®

Management Module (IMM) features

Professional Edition features

The Professional Edition includes the following features:

All the features provided by the mBMC

Support for IPMI v2.0 specification

Additional sensors

Temperature-based fan speed control by the BMC

Additional FRU records are visible to the management controller and management
software applications (for example, Power Supply, DIMM, and hot-swap controller
FRU’s)

The size of the System Event Log (SEL) is increased from 92 entries to 3276 entries

The number of BMC users is increased from one anonymous user to four users (each
with configurable user names and passwords on each LAN or Serial channel)

The IPMI 2.0 serial features are supported. The serial port can be used for console
redirection, Terminal-mode CLI, dial paging, Serial Over LAN (SOL), and other
management functions.

The Intelligent Chassis Management Bus (ICMB) is supported

8510702.book Page 46 Thursday, July 7, 2005 11:21 AM