Converting to pedestal configuration

To convert your server to a pedestal configuration, you need a pedestal conversion kit. To
order the conversion kit, contact Gateway Customer Care, Gateway Sales, or visit

accessories.gateway.com

. For more information on contacting Customer Care, see

“Telephone support” on page 223.

Contents of the conversion kit

The pedestal conversion kit contains the following:

Outer cover (1)

Phillips screws (6)

Caster assemblies (4)

Pedestal face plate (1)

Torx screws (6)

Tools required

You need the following tools to convert to the pedestal configuration:

Phillips head screwdriver (#2)

Torx screwdriver

To convert your server to the pedestal configuration:

1

Follow the instructions in

“Preventing static electricity discharge” on page 65

.

2

Remove the server from the rack cabinet, if necessary.

3

Remove the slide rails and cable management arm (if installed).

4

Remove the optional control panel (if installed), by following the instructions in

“Removing and installing the control panel” on page 84

.

Warning

Lifting the server or removing it from the rack is a two-person job. If
needed, use an appropriate lifting device. A fully loaded Gateway
9715 server weighs about 130 lbs (60 kg).