Chapter 7: Troubleshooting

Diagnostic POST LEDs

The BIOS sends a code (in raw binary) to port 80 prior to each POST task. These codes
are displayed on eight LEDs, located on the system board, which can be read by the user
and can provide troubleshooting information in the event of a system hang during POST.
For the location of these LEDs, see

“System board” on page 5

.

Power supply
status (3)

Power supply
module status

On each power
supply module

Green and
Orange

Top LED (green) - On means
power is good

Middle LED (orange) - On
means there is a fault
condition in this power supply
module

Bottom LED (green) - On
means that AC power to this
power supply module is OK.

POST Code
diagnostic LEDs
0-7 (LSB, bit1,
bit2, bit3, bit4, bit5,
bit6, MSB) bottom
to top

Display boot 80
POST code

On the left back
of the system
board

Each LED
can be
Off,
Green,
Orange,
or Red

See Post Code Table below

Fan fault

Indicate fan
failure

On each
hot-swap fan

Orange

On = Fault

LED reference designator

Bit

Example: Initialize memory

DS7D2

7 (MSB)

0x27

DS7D3

6

DS7D4

5

On

DS7D5

4

DS7D6

3

DS7D1

2

On

DS7D2

1

On

DS7D3

0 (LSB)

On

LED Name

Function

Location

Color

Description