Chapter 7: Troubleshooting

Additional beep codes provided by Intel Management
Modules

In addition to the beep codes above, the following additional beep codes are provided by
the Intel Management Module:

4

Recovery complete

FFh

BIOS recovery succeeded, ready
for power-down and reboot.

Beep Codes

Description

1

Control panel CMOS clear has been initiated

1-5-1-1

Processor failure. Reseat or replace the failed processor.

1-5-2-1

No processor is installed or the CPU 1 socket is empty. Reseat or
replace the failed processor.

1-5-2-2

No processors

1-5-2-3

Processor configuration error or CPU 1 socket is empty. Reseat or
replace the failed processor. In a two-processor system, make sure
the processors are identical.

1-5-2-4

Front-side bus select configuration error.

1-5-4-2

DC power unexpectedly lost.

Beeps

Error Message

POST Progress Code

Description