Setting serial port parameters

To be compliant with IT or other policies the console parameters can be changed from the CLI

interface. This is best done by setting the IP address and then telnet over to the switch. Once

connected using telnet, the serial parameters can be changed. If you are using the serial port,

remember to set the VT-100 emulation software properties to match the new settings.

Syntax set serial [baud=] [data=<5|6|7|8>] [parity=]

[stop=<1|1.5|2>] [flowctrl=]

Where = standard supported baud rates


Warning – changing these parameters through the serial port will cause loss of
connectivity – the parameters of the terminals software (e.g. Hyper Terminal etc.)
will also have to be changed to match the new settings.


To see the current settings of the serial port, use the ‘show serial’ command.

Magnum6K25#

show serial

Baud Rate

: 38400

Data

: 8

Parity

: No Parity

Stop

: 1

Flow Control

: None

F

IGURE

30

-

Querying the serial port settings

System parameters

The system parameters can be queried and changed. To query the system parameters, two

commands are used frequently. They are ‘show sysconfig’ and ‘show setup’. Both the

commands are shown below.

Magnum6K25#

show setup

Version

: Magnum 6K25 build 14.1 Jul 28 2008 07:51:45

MAC Address

: 00:20:06:25:b7:e0

IP Address

: 67.109.247.197

Subnet Mask

: 255.255.255.224

Gateway Address : 67.109.247.193

CLI Mode

: Manager

System Name

: Magnum6K25

System Description

: 25 Port Modular Ethernet Switch