M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

to 5 users to be added. Right now, the MNS-6K agent only support noauth and auth-md5 for v3
authentication and auth-des for priv authentication


Syntax show-user [id=] - display all or specific view entries - id is optional and is the number

corresponding to the view entry number in the table


Syntax
rmon – enter the RMON configuration mode to setup RMON groups and communities

Syntax
history def-owner= def-comm= - define the RMON history group and the

community string associated with the group


Syntax statistics def-owner= def-comm=- define the RMON statistics group and

the community string associated with the group


Syntax alarm def-owner= def-comm= - define the RMON alarm group and the

community string associated with the group


Syntax event def-owner= def-comm= - define the RMON event group and the

community string associated with the group


Syntax show rmon - list the specific RMON data as defined by the group

type

Chapter 21 – Miscellaneous
Commands

Syntax alarm – enter the alarm configuration mode

Syntax
add event= - enables alarm action in response to the specified event ID

Syntax
period time=<1..10> - sets the duration of relay action for the momentary type signal. This may be

needed to adjust to the behavior of the circuit or relay. Default is 3 seconds. Time is in seconds


Syntax
del event= - disables alarm action in response to the specified event ID

Syntax
alarm - globally enables or disables the alarm action

Syntax show alarm - displays the current status of Alarm system

Syntax
set motdafter the command is typed, MNS allows you to enter the Banner message

Syntax show motddisplays the current message set