Chapter 21 – miscellaneous commands – GarrettCom MNS-6K 4.1.4 User Manual
Page 301

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E
to 5 users to be added. Right now, the MNS-6K agent only support noauth and auth-md5 for v3
authentication and auth-des for priv authentication
Syntax show-user [id=
corresponding to the view entry number in the table
Syntax rmon – enter the RMON configuration mode to setup RMON groups and communities
Syntax history def-owner=
community string associated with the group
Syntax statistics def-owner=
the community string associated with the group
Syntax alarm def-owner=
community string associated with the group
Syntax event def-owner=
community string associated with the group
Syntax show rmon
type
Chapter 21 – Miscellaneous
Commands
Syntax alarm – enter the alarm configuration mode
Syntax add event=
Syntax period time=<1..10> - sets the duration of relay action for the momentary type signal. This may be
needed to adjust to the behavior of the circuit or relay. Default is 3 seconds. Time is in seconds
Syntax del event=
Syntax alarm
Syntax show alarm - displays the current status of Alarm system
Syntax set motd – after the command is typed, MNS allows you to enter the Banner message
Syntax show motd – displays the current message set
300