FUJITSU INTEGRATED REMOTE MANAGEMENT CONTROLLER IRMC S2/S3 User Manual
Page 407

iRMC S2/S3
407
IPMI OEM Commands supported by the iRMC S2/S3
F5 45 - Get SEL Entry Text
This command translates a given System Event Log SEL entry into ASCII text.
Request Data
-
B8
NetFnlLUN: OEM/Group
-
F5
Cmd : Command Group iRMC
1:3
80 28 00
IANA-Enterprise-Number FTS, LS Byte first
4
45
Command Specifier
5:6
Record ID of SDR, LS Byte first
Response Data
-
BC
-
F5
1
Completion Code
2:4
80 28 00
IANA-Enterprise-Number FTS, LS Byte first
5:6
Next Record ID
7:8
Actual Record ID
9
Record type
10:13
Timestamp
14
Severity:
Bit 7:
0 = No CSS component
1 = CSS component
Bit 6-4:
000 = INFORMATIONAL
001 = MINOR
010 = MAJOR
011 = CRITICAL
1xx = Unknown’
Bit 3-0:
reserved, read as 0000
15
Data length
16:35
Converted SEL data