Scheduled power – FUJITSU INTEGRATED REMOTE MANAGEMENT CONTROLLER IRMC S2/S3 User Manual
Page 202
202
iRMC
S2/S3
Power Consumption
Enable Power Monitoring
If you enable this option, power consumption is monitored over time.
I
Power monitoring is enabled by default as of Version 3.32 of the
firmware.
I
This setting only takes effect on PRIMERGY servers that support
power monitoring.
Ê
Click
Apply
to activate your settings.
Scheduled Power Consumption Configuration
The
Scheduled Power Consumption Configuration
group allows you to specify in
detail the schedules and modes (operating-system-controlled, best
performance, lowest power consumption) that the iRMC S2/S3 uses to control
power consumption on the managed server.
I
The
Scheduled Power Consumption Configuration
group only appears if you
have enabled the power control mode
scheduled
in the
Power Consumption
Options
group.
I
Configuration for scheduled power control mode assumes that the
Enhanced Speed Step
option has been enabled in the BIOS setup. If this is
not the case, a message to this effect is displayed.
If this message appears even though “Enhanced Speed Step” is
enabled, this may be because:
–
The CPU (e.g. low-power CPU) of the server does not support
scheduled power control.
–
The system is currently in the BIOS POST phase.